Combined 5.2.1 test run: everything about the installer, the base images, Tomcat and Domino, and the tested upgrade path from 5.2.0.
Data Miner 2.5.1: release build and its GreenLight checks (C6).
GreenLight web application: the 5.2.1 build contains the user administration and HTML User Simulation fixes; other web application changes since 5.2.0, if any.
Java: the release images must carry Temurin 17.0.21.1 in the Tomcat template (both JDKs) and JDK 25.0.5.1 in Metabase. The 5.2.1 test images of 2026-11-19 still have 17.0.20.1 and 25.0.5. Otherwise the Java entry and the two Java rows go back to the precaution wording.
PostgreSQL index check on GreenLight, offline installer size.
Owner’s decisions: the note box, the content collision line, the backup and rollback sentence.
We just announced a new release of GreenLight, the Monitoring Solution for HCL Domino and others.
This version is a maintenance release with security updates of the underlying components and Data Miner, fixes in the GreenLight web application, and a server address check in the installer.
Recommended Security Update
This release fixes a security issue in the Data Miner login that GreenLight uses, together with security updates of the web server, the database and the Java runtimes. We recommend upgrading all GreenLight installations.
Improvements
Allowed Browser Addresses (CORS): The installer and
gl hostnamenow setPANAGENDA_CORS_ALLOWED_ORIGINStohttps://<server address>when it is missing, still the defaulthttps://localhost, or was set by them for an earlier address. A value you set yourself is kept; the installer warns when the server address is not in it. The CORS question during upgrades is gone, so an upgrade without a terminal no longer stops there.Metabase AI Features: Metabase’s AI features are off by default, and the setting is locked in Metabase’s admin settings. To turn them on, set
PANAGENDA_METABASE_AI_FEATURES_ENABLED=truein/opt/panagenda/appdata/gl/configand rungl recreate; an AI provider must also be configured in Metabase.Metabase Site URL: Metabase’s Site URL now comes from the appliance configuration:
https://<server address>/metabase, or the value ofPANAGENDA_METABASE_SITE_URLif set. It is locked in Metabase’s admin settings. See What Changes for Administrators below.Offline Installer: The offline installer loads its images directly from the package and needs much less temporary space. If the space is still too small, it shows how to use another directory.
Server Address Check: On installation and upgrade, the installer checks the address users open GreenLight under against DNS before it stops the running version, and asks only when the address is not clear. A confirmed address is kept on later upgrades; without a terminal, the best candidate is taken. At the end, the installer shows the server address, the URLs and a reachability check. The new command
gl hostnameshows or changes the address, and GreenLight’s alert e-mails use it as the host name.
Infrastructure / Security
Alpine Linux 3.24: Several of the containers that make up the GreenLight application are now based on Alpine Linux 3.24 and include its most current security fixes.
Java Vulnerability CVE-2026-114938: The Java runtimes of the GreenLight web application and of Metabase, the two Java services reachable from the network, have been updated to versions that fix CVE-2026-114938 (“Java4Shell”). As an additional precaution, the affected Java feature is switched off in both.
nginx 1.30.7: The web server nginx has been updated from 1.30.3 to 1.30.7, which includes the upstream security fixes of versions 1.30.4 to 1.30.7 (see the nginx security advisories).
PostgreSQL 15.20: The database has been updated from PostgreSQL 15.19 to 15.20, an upstream release with security fixes (see the PostgreSQL 15.20 release notes). The update keeps the existing data directory; no dump and restore is needed.
Tomcat 9.0.123 and Domino 12.0.2 FP8: The GreenLight web application now runs on Tomcat 9.0.123 with the Domino 12.0.2 FP8 libraries.
Bug Fixes
Data Miner 2.5.1: Fixed a security issue in the GreenLight login and HTTP Basic authentication of Data Miner, and an issue with the redirects after login and logout. GreenLight users whose password GreenLight stores in bcrypt form can now log in to Data Miner; they were refused before. Data Miner sessions no longer contain the stored password hash, the request parser has been updated, and the log no longer contains query results or login details. GreenLight moves from Data Miner 2.1.1, so the fixes and security updates of Data Miner 2.5.0 are included as well. See What Changes for Administrators below.
Data Miner Login: Fixed the error message after a failed Data Miner login, which showed “undefined”. User names containing quotes now work, and overlapping logins no longer hang.
Data Miner Query Requests: Fixed an issue where a malformed query request could affect Data Miner for all users. Such requests are now refused with an error.
HTML User Simulation Sensor: Fixed the sensor with authentication set to None, which requested the server root instead of the configured path and could therefore report HTTP 200 although the configured URL returned 404. It now requests the configured path and query string and reports that URL’s status.
Installer Configuration File: Fixed settings that the installer adds to
/opt/panagenda/appdata/gl/configbeing joined to the last line when the file did not end with a line break. The installer now also warns about lines that already hold more than one setting.Installer Rollback Advice: Fixed rollback commands shown after an upgrade that stopped before taking its own snapshot; they pointed to the snapshot of an earlier upgrade.
User Administration: Fixed an error when enabling or disabling a user without entering a password. The existing password stays unchanged; a new password, if entered, is saved.
Structural Changes / Upgrade Path
Component Upgrades inside Containers
The following components inside the containers have been updated.
| Component | 5.2.0 | 5.2.1 |
|---|---|---|
| Alpine Linux (base of the web server, cron and database containers) | 3.23 | 3.24 |
| Data Miner | 2.1.1 | 2.5.1 |
| Domino libraries | 12.0.2 FP7 IF1 | 12.0.2 FP8 |
| Java runtime (GreenLight web application) | 17.0.20 | 17.0.21.1 |
| Java runtime (Metabase) | 25.0.4 | 25.0.5.1 |
| Metabase | 0.62.19.4 | 0.62.19.6 |
| nginx | 1.30.3 | 1.30.7 |
| PostgreSQL | 15.19 | 15.20 |
| Tomcat | 9.0.121 | 9.0.123 |
What Changes for Administrators
Run the upgrade in an interactive session: The first upgrade to 5.2.1 checks the server address and may ask you to confirm it. Run it in an interactive ssh session; without a terminal, the installer takes the best candidate.
Metabase Site URL: A Site URL set by hand in Metabase is replaced by
https://<server address>/metabase. Note your current Site URL before upgrading. If it differs, choose that address when the installer asks for the server address, or setPANAGENDA_METABASE_SITE_URLin/opt/panagenda/appdata/gl/config.Allowed browser addresses: If users reach GreenLight under another address, for example through a reverse proxy or a DNS alias, keep your own value of
PANAGENDA_CORS_ALLOWED_ORIGINSand make sure it lists every such address. WhenPANAGENDA_METABASE_SITE_URLis set, the installer neither sets nor checks this value.Data Miner database roles: The update resets the passwords of the database roles
cqx_basicandcqx_proand re-applies their permissions. If you changed these passwords, for example for direct SQL access from reporting tools, set them again after the update.Data Miner log files: Log files written before the update may contain query results and login details. Review the older files in
/opt/panagenda/logs/data-minerand delete those you no longer need. If clients sent their credentials as URL parameters, change those passwords.Data Miner query IDs: Query IDs in API calls and saved URLs must be plain positive numbers; forms such as
007or+7are now refused.Data Miner features retired: Advanced server-side SQL templates and the downloads from the hosted query store are no longer available. Local saved queries, manual imports and exports remain.
Metabase content: The upgrade replaces the dashboards and questions panagenda ships. Make your own changes in copies, not in the originals. The Metabase upgrade log (
/opt/panagenda/logs/metabase-upgrade_*.log) lists what the upgrade removed, and your collections that an earlier upgrade opened to all users; check the permissions of those collections.Metabase content not upgraded: If the installer reports that the Metabase content was not upgraded because of a content collision, GreenLight keeps running with the previous content. Do not roll back and do not run the upgrade again; contact panagenda support.
Tools on your own Linux host: The installer now needs
getentandtimeout;curlis recommended for the final reachability check.New boxes from an appliance image: After deploying a GreenLight appliance image, run
gl hostnameonce, so that the server address and the allowed browser addresses are set.
Upgrade Procedure: Container Installer
Details on how to update to this new version can be found in the knowledge base article Upgrading GreenLight. Back up the database before you upgrade: going back to 5.2.0 after a completed upgrade means restoring that backup and reinstalling 5.2.0. The upgrade from 5.2.0 to 5.2.1 has been tested. If you upgrade from 5.0 or 5.1, also read the Release Notes v5.2.0.